Details
Applications
For clean liquids without abrasives, without suspended solids, non-explosive, non-aggressive pump materials. For increasing network pressure. The reduced dimensions mean this pumps are suitable to be mounted in cooling, air-con, circulation and boiler systems
Operating Conditions
- Liquid temperature from -10°C to +90°C
- Ambient temperature up to 40°C
- Total suction lift up to 7m.
- Continuous duty.
Motor
- 2-Pole induction motor, 50Hz (n="2900" rpm).
- T, TP: three-phase 230/400v
- TM, TPM: Single-phase 230v 10% with thermal protector and capacitor inside the terminal box
- Insulation class F.
- Protection IP54
- Constructed in accordance with IEC 60034; IEC 60335-1 (EN 60335-1)